EFFECT OF SALT COMPOSITION ON THE SEPARATION PROFILE OF CONTAMINATED GROUNDWATER IONS BY ELECTRODIALYSIS
DOI : 10.21660/2018.52.56077
Date : DEC 2018
Chloride, nitrate, sulfate, and fluoride ions are sometimes available in groundwater at an elevated level, which is harmful to humans and the environment. The membrane separation technique has been widely explored for controlling the level of those ions in drinking water, particularly the electrodialysis method. In the present study, divalent (AMX) and monovalent ion selective (ACS) anion exchange membranes were used to remove the high concentrations of chloride and other co-existent ions from groundwater samples. The study focuses on the effect of the composition of the salt in the groundwater on the reducing profile of ions, the number of deionized ions, and the rate of ion removal in the diluting compartment. To achieve these experimental objectives, two series of ion samples composed of sodium and calcium were designed. The compositions of the ions were NaCl, Na2NO3, Na2SO4 for the Na-compound, and CaCl2, Ca(NO3)(2)center dot 4H(2)O, CaSO4 center dot 2H(2)O, and CaF2 for the Ca-compound. The electrodialysis experiment was run at a constant applied voltage (8 volts), using sodium nitrate as the electrode solution. In summary, the ED performance for all the investigated parameters was better in the case of ions composed of sodium. Furthermore, a change in the applied current against the electrodialysis operation time was also observed. The results indicated that the current requirement by ED to separate ions composed of calcium needed to be slightly higher than that for ions composed of sodium.